Characteristics:
Save
Energy
see more…
Characteristics:
Heat
Isolation
Solution
see more…
Characteristics:
Save
Energy
see more…
Characteristics:
Save
Energy
see more…
Characteristics of the glass unit:
1. Heat transfer coefficient (Ug) is the amount of heat in watts, which is transferred per unit through 1sq. m of glass per degree Kelvin difference from internal and external temperature (Ug=W/m2K). This is the most important feature of a glazing. Small value of Ug coefficient means less loss of heat and less expenses of heating during the winter.
2. Noise insulation (Rw) Rw Index measures noise insulation of the glass unit. The higher the value of the index is, the better the noise insulation. l UV (%) – harmful ultra-violet rays passing through, leading to fading of colors and causing skin cancer
3. Solar factor (%) sum of all direct passed energy and part of it that was absorbed from glass which is emitting from window to the inner space, I. e., the whole quantity of energy that passes through glass unit. The more the direct reflectance of solar energy from the glass is, the lower the solar factor is and less the expenses for air-conditioning in summer months are.
4. Light-transmission (%) visible light that passing through glass. The less the value in %, the darker is the premise
5. Reflection (%) the amount of the reflected light by glass package. The bigger the % of the reflection of the glass, the greater is its reflexivity

Low-e glass
- Improves solar and thermal control
- Reduces UV transmission
- Relatively inexpensive
- Reduce solar heat gain in winter

Toned Glass
- Reduces heat and glare
- Reduces cooling costs
- improves privacy
- Decreases visibility and light

Laminated Glass
- Harder to break
- Reduces noise
- Cuts down UV transmission
- Exposure to water can cause deterioration

Window Film
- Film is an effective and affordable way to keep heat out and also helps to reinforce your windows for safety.
Single | ||||||||
---|---|---|---|---|---|---|---|---|
Glass Unit* | Size, mm |
Ug with Air(1) |
Ug with argon gas(1) |
Rw, dB(2) |
Uv, %(3) |
Solar factor % |
% (4) |
% (5) |
W | 4 | 5.8 | – | 23 | 69 | 86 | 90 | 8 |

Double | ||||||||
---|---|---|---|---|---|---|---|---|
Glass Unit* |
Size, mm |
Ug with Air(1) |
Ug with argon gas(1) |
Rw, dB(2) |
Uv, %(3) |
Solar factor % |
% (4) |
% (5) |
W/W |
24 | 2.7 | 2.6 | 30 | 54 | 77 | 81 | 15 |
W/LE |
24 | 1.4 | 1.1 | 30 | 34 | 62 | 79 | 12 |
HE/L |
24 | 1.4 | 1.1 | 35 | 3 | 42 | 66 | 26 |
HE/W |
24 | 1.3 | 1.0 | 30 | 25 | 42 | 66 | 26 |

Triple | ||||||||
---|---|---|---|---|---|---|---|---|
Glass Unit* |
Size, mm |
Ug with Air(1) |
Ug with argon gas(1) |
Rw, dB(2) |
Uv, %(3) |
Solar factor % |
% (4) |
% (5) |
HE/W/LE |
32 | 1.0 | 0.8 | 32 | 15 | 38 | 60 | 29 |
HE/W/LE |
36 | 0.9 | 0.7 | 32 | 15 | 38 | 59 | 29 |
HE/W/LE |
40 | 0.8 | 0.6 | 35 | 15 | 38 | 60 | 29 |
HE/W/LE |
44 | 0.7 | 0.5 | 35 | 15 | 38 | 60 | 29 |
HE/W/LE |
50 | 0.7 | 0.5 | 35 | 15 | 38 | 60 | 29 |
LE/W/LE |
32 | 1.1 | 0.8 | 32 | 20 | 49 | 71 | 15 |
LE/W/LE |
36 | 0.9 | 0.7 | 32 | 20 | 49 | 71 | 15 |
LE/W/LE |
40 | 0.8 | 0.6 | 35 | 20 | 49 | 71 | 15 |
LE/W/LE |
44 | 0.8 | 0.6 | 35 | 20 | 49 | 71 | 15 |
LE/W/LE |
50 | 0.7 | 0.5 | 35 | 19 | 49 | 71 | 15 |
* Types of glass, legend: W – WHITE L – LAMINATED LE – LOW EHIGH ENERGY HE – HIGH ENERGY